Superior Courts Act, 2013
R 385
Occupational Health and Safety Act, 1993 (Act No. 85 of 1993)Code of PracticeNational Code of Practice for Electrical Machinery in Hazardous LocationsRegulatory requirements for explosion-protected apparatusAnnexesAnnex F (normative) : Minimum requirements for an Accredited Test Laboratory to be approved |
ANNEX F
(normative)
Minimum requirements for an Accredited Test Laboratory to be approved
| F1. | When a test laboratory intends to be accredited to test against a standard then the test signatory is required to have the following: |
| • | experience at a test laboratory in the testing of equipment to that standard; |
| • | evaluation of results of tests conducted by the signatory of another test laboratory |
| F2 | The new test laboratory must have the following equipment and the necessary calibration certificates: |
|
General - 60079-0 |
|
|
Resistance to impact |
required |
|
Drop test |
required |
|
Degree of protection |
required |
|
Measurement for maximum surface temperature |
required |
|
Thermal endurance to heat |
required |
|
Thermal endurance to cold |
required |
|
Surface resistivity |
required |
|
Measure of capacitance |
|
|
Flameproof - 60079-1 |
|
|
Determination of explosion pressure (reference pressure) |
required |
|
Overpressure test (static) |
required |
|
Overpressure test (dynamic) |
|
|
Test for non-transmission of internal ignition |
required |
|
Tests of ability of enclosure to withstand pressure (breathing and draining devices) |
|
|
Thermal tests (breathing and draining devices) |
|
|
Test for non-transmission of internal ignition (breathing and draining devices |
|
|
Pressurization - 60079-2 |
|
|
Maximum overpressure test |
required |
|
Leakage (other than static pressurization) |
|
|
Static pressurization |
required |
|
Purging test for pressurized enclosures (where the protective gas is air) |
required |
|
Purging test for pressurized enclosures (where the protective gas is inert) |
required |
|
Purging test for pressurized enclosures (where the protective gas may be either air or an inert gas with a density equal to air ± 10%) |
required |
|
Filling procedure test for a pressurized enclosure protected by static pressurization |
required |
|
Purging and dilution test for pressurized enclosure with an internal source of release |
required |
|
Pressurized enclosures where the flammable substance has less than 2% (V/V) oxygen and the protective gas is inert |
required |
|
Pressurized enclosures with pressurization by continuous flow, containment system with less than 21% (V/V) oxygen and the protective gas is inert |
required |
|
Pressurized enclosure where the flammable substance is not a liquid, pressurization by continuous flow and the protective gas is air |
required |
|
Verification of minimum overpressure |
required |
|
Overpressure test (infallible containment system) |
required |
|
Infallibility test (infallible containment system) |
required |
|
Overpressure test for a containment system with limited required release |
required |
|
Verifying ability of the pressurized enclosure to limit internal pressure |
required |
|
Powder filling - 60079-5 |
|
|
Pressure type test of enclosure (type verification) |
required |
|
Flammability of materials |
|
|
Dielectric strength test of the filling material |
required |
|
Maximum temperatures |
required |
|
Routine pressure test of enclosure (routine verification) |
required |
|
Dielectric strength test of the filling material (routine verification) |
required |
|
Increased safety - 60079-7 |
|
|
Dielectric strength |
required |
|
Rotating electrical machines |
|
|
Measuring instruments and instrument transformers |
|
|
Transformers other than instrument transformers |
|
|
Secondary batteries |
|
|
General purpose connection and junction boxes |
required |
|
Resistance heating devices and resistance heating units |
|
|
Terminal insulating material test |
required |
|
Intrinsic safety - 60079-11 |
|
|
Spark ignition assessment |
required |
|
Temperature test |
required |
|
Voltage test |
required |
|
Small component ignition test |
required |
|
Tests for cells and batteries |
required |
|
Mechanical test - casting compound |
required |
|
Mechanical test - partitions |
required |
|
Test for apparatus containing piezoelectric devices |
required |
|
Type test for diode safety barriers and safety shunts |
|
|
Cable pull test |
required |
|
Dielectric strength test |
required |
|
Mechanical test - sealing of components before encapsulation |
required |
|
Transformer test |
required |
|
Type of protection "n" electrical apparatus - 60079-15 |
|
|
Test for enclosed-break devices and non-incendive components |
required |
|
Tests for sealed devices and encapsulated devices |
required |
|
Tests for restricted-breathing enclosures |
required |
|
Mechanical shock test for batteries |
|
|
Insulation resistance test for batteries |
|
|
Additional ignition tests for large or high-voltage machines |
|
|
Protection by encapsulation - 60079-18 |
|
|
Test on the compound - water absorption |
required |
|
Test for resettable thermal protective device |
required |
|
Conditioning / Thermal cycling |
required |
|
Sealing test for build-in protective devices |
required |